- How does the slotted agi pipe attach to the inlet?
The 1m long slotted agi pipe (slotted drain coil) slips over the short poly-pipe section at the bottom of the inlet. No screws are required as the screenings hold that assembly in place.
The short 20cm slotted agi pipe at the outlet is screwed onto the internal thread on the tank fitting with a single small crew. Take precautions and be careful not to damage the liner during this part of the installation.
The agi pipes do not require end caps to function correctly. The 7mm screenings will fall into the ends a short distance and will not completely block the pipes.
- The ag pipe is shorter than the bed in the video instructions. Is that right?
Often, yes. Our standard 1 m slotted inlet agi pipe is standard for beds up to about 3.5 m long when built with the recommended 5-7 mm screenings. Water spreads through the reservoir easily with this sized aggregate and the agi pipe mainly justy gets it started.
Our instruction videos are great but getting on in age and some show a longer pipe. We will eventually update these videos but we have been a little busy creating bespoke edible gardens and wicking beds. 🙂
Extra-long beds, unusual shapes or a different reservoir material can sometimes benefit from custom lengths. In some cases with extra long beds and the inlet and outlet at opposing ends a longer pipe can help speed up the time it takes to see the water level balance out at the outlet pipe end. so make sure to get in touch if your bed is extra large and we can advise on if more agi pipe is needed.
- Do corrugated metal beds need a special gasket for the outlet?
Yes. Corrugated metal garden beds, including Birdies beds, require a special gasket or adapter to create a flat, watertight sealing surface for the outlet fitting. Our corrugated gasket is designed to suit standard Colorbond-style corrugations and also allows the outlet fitting to be securely attached to the metal bed.
The gasket is available as an optional extra on our Custom Wicking Bed Conversion Kit page. You'll need one gasket per bed.
If your bed has an unusual corrugated profile, contact us with a photo and measurements before ordering. We provide detailed installation instructions with your kit.
- How do I set the overflow and check for leaks before adding soil?
Before adding soil, it's important to set your overflow height correctly and check for leaks. This is much easier to do before the bed is completely filled.
The VEG wicking bed system uses an adjustable external outlet pipe (riser) to control the maximum water level in the reservoir. The aim is to keep the water just below the top of the screenings, preventing the soil from becoming waterlogged.
Follow these steps:
- Fill and level the reservoir: Add water through the inlet pipe and use the water surface as a guide to level your screenings. The screenings should be evenly distributed, with no significant high or low spots.
- Set the overflow height: Drain any excess water until the screenings look wet but there are no puddles on the surface. Adjust the external riser so its overflow height matches this level, at or just below the top of the screenings. If necessary, shorten the riser using suitable pipe cutters or a fine-toothed hacksaw. Measure carefully before cutting.
- Check for leaks: Inspect the outlet fitting, plumbing connections and outside of the bed for escaping water. Once the overflow has stopped running, leave the reservoir overnight if possible and check for unexpected water loss or damp patches around the bed.
Once you're happy that the outlet is working correctly and there are no leaks, install the geotextile separation layer and add your soil.
Tip: Setting the overflow correctly is important for maintaining the separation between the water reservoir and soil, helping prevent waterlogging and anaerobic conditions. Refer to your VEG installation instructions or contact us if you're unsure about your setup.